Front page >Product Center >Industrial Automation >Servo Drive >TRIO AC Servo Drive

DX4 Series AC Servo Drive

The DX4 Series AC Servo Drive is a flagship product that combines high performance and high reliability. With its streamlined software and hardware design and outstanding product highlights, it provides a flexibly scalable servo solution for automated motion control equipment. The product covers a power range of 50 W to 3 kW, adapting to multi-scenario motion control requirements; it also supports the EtherCAT communication protocol, ensuring stable and efficient signal transmission in industrial scenarios and providing strong drive support for the operation of automation equipment.

Drive Model:DX4-

1A5A

101A

102A

104A

108A

110A

115A

120A

130A

Continuous Output Current [Arms]

0.9

1.1

1.5

2.9

5.1

6.9

8.2

11.3

16

Maximum Output Current [Arms]

3.3

4

5.8

11.5

19.5

21

24.6

33.9

54

Main Power Equipment Capacity [kVA] 

Single-Phase

0.2

0.3

0.6

1.2

1.9

2.6

4

-

-

Three-Phase

0.2

0.3

0.5

0.9

1.6

2

3

3.5

4.5

Input Power

Main Circuit

Single-Phase or Three-Phase AC 200 V ~ 240 V, -15% ~ +10%, 50 Hz / 60 Hz

When used with a single-phase power supply, DX4-115 is derated to 1.2 kW, and DX4-120 and DX4-130 can only be used with a three-phase power supply.

Control Circuit

Single-Phase AC 200 V ~ 240 V, -15% ~ +10%, 50 Hz / 60 Hz

Control Method

SVPWM

Operating Conditions

Temperature

Operating Temperature: -5°C ~ 55°C (when close-mounted, the maximum operating temperature is 40°C); Storage Temperature: -20°C ~ +85°C

Humidity

Operating Humidity and Storage Humidity: 5% ~ 95% (Non-Condensing, Non-Freezing)

Protection Rating

IP20

Altitude

Below 1,000 m

Vibration Resistance

4.9m/s²

Shock Resistance

19.6m/s²

Power System

TN System

Mounting Structure: Base Mounting

Performance

Speed Control Range

1:5000

Speed Fluctuation

Within ±0.01% of rated speed (load fluctuation: 0% ~ 90%);

Within ±0.1% of rated speed (temperature fluctuation: 25°C ± 25°C)

Second Encoder Input

Supports differential sensor signals for Phase A, Phase B, and Phase Z, Maximum input frequency is 500 kHz

Input/Output Signals

 Input Signals

 Operating Voltage Range: 24 VDC ± 20%; Number of Input Channels: 7, of which 2 channels are high-speed optocoupler inputs fixed for Touch Probe; the other input signals are general-purpose inputs, all of which can be assigned and their positive/negative logic can be changed during commissioning.

Output Signals

Operating Voltage Range: 5 VDC ~ 30 VDC; Number of Output Channels: 4; all output signals are general-purpose outputs, all of which can be assigned and their positive/negative logic can be changed during commissioning.

 

Drive Model:DX4-

1A5A

101A

102A

104A

108A

110A

115A

120A

130A

CiA402 Drive ProFile

Cyclic Synchronous Position Mode
Cyclic Synchronous Velocity Mode
Cyclic Synchronous Torque Mode
Touch Probe Function
Torque Limit Function

Display

One 7-Segment LED Digital Tube

Indicators

CHARGE、POWER、RUN、SYS、ERR、L/A IN、L/A OUT

 Regenerative Braking

DX4-1A5, DX4-101, DX4-102, and DX4-104 require an external braking resistor.

Protection Functions

Overcurrent, Overvoltage, Undervoltage, Overload, Regenerative Abnormality, Overspeed, etc.

Auxiliary Functions

Alarm History, Jog Operation, Load Inertia Identification, Mechanical Analyzer, Auto-Tuning, etc.

Safety Function STO

According to IEC 61800 - 5 - 2. Cat.4, PLe according to ISO 13849 - 1

 

 