Front page >Product Center >Industrial Automation >Industrial Safety >Safety Controller

SAFETY CONTROLLER

SMX GEN2 Compact Security Controller for Security Programs

Summary: From small signal I/O processing to complex drive monitoring, SMX compact ensures the completion of every safety task.

Basic Module

SMX GEN2 Compact

  1. 01

    PL e in accordance with EN ISO 13849-1 standard or SIL 3 logic processing function in accordance with IEC 61508 standard

  2. 02

    SMX Gen2, combined with safety fieldbus communication and F-Host, can solve tasks such as safety position monitoring, area detection, multi axis functionality, and collision monitoring

  3. 03

    A small controller that can support up to 800 AWL instructions for free programming

  4. 04

    Up to 2 compact modules can be configured

  5. 05

    Maximum support for driving monitoring of 2 axes

  6. 06

    Supports OPC UA gateway for easy process data exchange

  7. 07

    Using SafePLC ² for functional diagram oriented programming

  8. 08

    Secure data exchange between multiple basic modules through Ethernet based protocols and SMMC (Secure Master Station Communication)

  9. 09

    Supports both secure and non secure fieldbus interfaces for connecting higher control levels (PROFIBUS, PROFINET, DeviceNET, EtherNet/IP, CANopen, Modbus TCP, EtherCAT, FSoE, PROFIsafe)

SMX10/2

  1. 0114 secure digital inputs
  2. 022 safety relay outputs
  3. 032 pulse outputs
  4. 042/4 PN or PP switch outputs
  5. 05Meets PL e (EN ISO 13849-1) or SIL3 (IEC 61508) safety level
CESMX10/2 safety controller

SMX10/2/xNM

  1. 0114 secure digital inputs
  2. 022 safety relay outputs
  3. 032 pulse outputs
  4. 042/4 PN or PP switch outputs
  5. 052/4 pn or pp switch output
  6. 06Meets PL e (EN ISO 13849-1) or SIL3 (IEC 61508) safety level
  7. 07Storage card for security programs
CESMX10/2/xNM safety controller

SMX11/2

  1. 01Integrated drive monitoring for 1 axis
  2. 023 encoder interfaces*
  3. 0314 secure digital inputs
  4. 04Up to 4 secure digital outputs
  5. 05Up to 5 secure shutdown channels
  6. 06Meets PL e (EN ISO 13849-1) or SIL3 (IEC 61508) safety level
CESMX11/2 safety controller

SMX100-2/2/xNM

  1. 0114 secure digital inputs
  2. 026 Auxiliary outputs
  3. 0320 secure digital inputs/outputs
  4. 042 safety relay outputs, 2 pulse outputs
  5. 052/4 pn or pp switch output
  6. 06Equipped with integrated drive monitoring for up to 12 axes
  7. 07Meets PL e (EN ISO 13849-1) or SIL3 (IEC 61508) safety level
  8. 08Ethernet based fieldbus interface, safe/non safe
CESMX100-2/2/xNM safety controller

SMX12/2

  1. 01Integrated driver monitoring, supporting up to 2 axes
  2. 024 encoder interfaces*
  3. 0314 secure digital inputs
  4. 04Up to 5 secure shutdown channels
  5. 05Meets PL e (EN ISO 13849-1) or SIL3 (IEC 61508) safety level
CESMX12/2 safety controller

SMX12/2/xNM

  1. 01Integrated driver monitoring, supporting up to 2 axes
  2. 024 encoder interfaces*
  3. 0314 secure digital inputs
  4. 04Up to 5 secure shutdown channels
  5. 05Meets PL e (EN ISO 13849-1) or SIL3 (IEC 61508) safety level
  6. 06Fielbus interface based on Ethernet, secure/non secure
  7. 07Storage card for security programs
CESMX12/2/xNM safety controller

SMX12/2/2

  1. 01Integrated driver monitoring function, capable of controlling up to 2 axes, with extended encoder functionality
  2. 028 Encoder Interface
  3. 0314 secure digital inputs
  4. 04Up to 5 secure shutdown channels
  5. 05Meets PL e (EN ISO 13849-1) or SIL3 (IEC 61508) safety level
CESMX12/2/2 safety controller

SMX12/2/xNM

  1. 01Integrated driver monitoring function, capable of controlling up to 2 axes, with extended encoder functionality
  2. 028 Encoder Interface
  3. 0314 secure digital inputs
  4. 04Up to 5 secure shutdown channels
  5. 05Meets PL e (EN ISO 13849-1) or SIL3 (IEC 61508) safety level
  6. 06Fielbus interface based on Ethernet, secure/non secure
  7. 07Storage card for security programs
CESMX12/2/xNM safety controller

Basic Module

SMX31/2

Central I/O expansion module of SMX GEN2 compact basic module

  1. 0112 secure digital inputs
  2. 0210 digital I/O
  3. 032 auxiliary/pulse outputs
  4. 04Meets PL e (EN ISO 13849-1) or SIL3 (IEC 61508) safety level
CESMX31/2 safety controller